EasyManuals Logo

Siemens SIMOTION D410 DP Commissioning Manual

Siemens SIMOTION D410 DP
230 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #42 background imageLoading...
Page #42 background image
Commissioning (hardware)
2.5 User memory concept
SIMOTION D410
42 Commissioning Manual, 02/2012
Table 2- 6 State of the non-volatile SIMOTION data after powering up (persistentDataState system
variable)
Status Meaning
FROM_RAM (1) Non-volatile SIMOTION data in the SIMOTION device is used
FROM_FILE (2) Non-volatile SIMOTION data is restored from the backup file
FROM_BACKUP (3) Non-volatile SIMOTION data is restored from the backup copy of the backup
file
INVALID (4) Data in the non-volatile SIMOTION data and in the backup file / backup copy
of backup file is invalid or non-existent/deleted.
The SIMOTION device has copied the default settings to the non-volatile
SIMOTION data and used this data to power up.

Table of Contents

Other manuals for Siemens SIMOTION D410 DP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION D410 DP and is the answer not in the manual?

Siemens SIMOTION D410 DP Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION D410 DP
CategoryControl Unit
LanguageEnglish

Related product manuals