EasyManuals Logo

Siemens SIMOTION D455-2 User Manual

Siemens SIMOTION D455-2
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
A SIMOTION D axis grouping generally consists of the following elements:
SIMOTION D (Control Unit) (1)
This
unit contains the programmable runtime system of SIMOTION and the drive software
of SINAMICS S120. In principle, SIMOTION D is capable of controlling multiple axes/drives.
One SINAMICS infeed (Line Module) (2)
This module generates a DC link from the supply system.
SINAMICS power units (Motor Modules) (3)
These modules are used to control motors.
It is also possible to operate SINAMICS Power Modules in blocksize format with the
SINAMICS Control Unit Adapter (CUA). A separate infeed is then unnecessary.
DRIVE-CLiQ components (4)
In SINAMICS S120 / SIMOTION D, the individual components of the drive system
communicate with each other via DRIVE‑CLiQ. In addition to power components, encoder
systems and special DRIVE‑CLiQ I/O devices can also be linked via DRIVE‑CLiQ.
Extension of the drive computing performance
The motion control performance of a SIMOTION D4x5‑2 can be utilized in full by expanding
the computing performance at the drive in two different ways:
SINAMICS S/G control units (e.g. CU320‑2, CU310‑2, CU305, CU250S‑2, etc.) complete
with further drive components can be connected via PROFIBUS or PROFINET.
With SIMOTION D4x5‑2, the CX32-2 controller extension can be connected via
DRIVE‑CLiQ. This module is extremely compact, does not require a separate
CompactFlash card and can control up to 6 servo, 6 vector or 12
V
/
f
axes.
Software components
The basic functionality of SIMOTION D is supplied on a CompactFlash card containing the
following:
The SIMOTION runtime system with the following functions:
Freely programmable runtime system (IEC 61131)
Various runtime levels (tasks)
PLC and arithmetic functionality
Motion control functions
Communication functions
The SINAMICS S120 drive control with the following functions:
Closed-loop current and torque control
Closed-loop speed control
Closed-loop infeed
Description
2.1 System overview
SIMOTION D4x5-2
24 Manual, 04/2014

Table of Contents

Other manuals for Siemens SIMOTION D455-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTION D455-2 and is the answer not in the manual?

Siemens SIMOTION D455-2 Specifications

General IconGeneral
BrandSiemens
ModelSIMOTION D455-2
CategoryControl Unit
LanguageEnglish

Related product manuals