Table 5-5 Power supply data
D425-2 DP
D435-2 DP
D425-2 DP/PN
D435-2 DP/PN
D445-2 DP/PN
D455‑2 DP/PN
Power supply
●
Rated value
● Permissible range
Safety extra-low voltage DVC A (PELV)
24 VDC
(20.4 ... 28.8 V)
Current consumption, typically
1)
0.7 A 1.0 A 1.9 A
Starting current, typically
1)
5 A 5 A 5 A
Power loss, typically
1)
17 W 24 W 46 W
1)
With no load on inputs/outputs, no 24 V supply via DRIVE‑CLiQ and PROFIBUS interfaces
Table 5-6
Input voltage specification
Input voltage D4x5-2
Minimum input voltage 20.4 V
Nominal input voltage 24 V
Maximum input voltage 28.8 V
Table 5-7
Specification of the input current - typical current consumption
Typical current consumption
1)
Device type D425-2 DP
D435-2 DP
D425-2 DP/PN
D435-2 DP/PN
D445‑2 DP/PN
D455‑2 DP/PN
Minimum input voltage 0.8 A 1.2 A 2.24 A
Nominal input voltage 0.7 A 1.0 A 1.9 A
Maximum input voltage 0.6 A 0.8 A 1.58 A
1)
With no load on inputs/outputs and no 24 V supply via DRIVE‑CLiQ or PROFIBUS interface
Table 5-8
Specification of the input current - maximum current consumption
Maximum current consumption
Device type D425-2 DP
D425-2 DP/PN
D435-2 DP
D435-2 DP/PN
D445‑2 DP/PN
D455‑2 DP/PN
Minimum input
voltage
12.8 A 13.6 A 13.9 A 14.6 A 18.35 A
Nominal input
voltage
10.9 A 11.5 A 11.8 A 12.4 A 15.6 A
Maximum input
voltage
9.1 A 9.6 A 9.8 A 10.3 A 13 A
Technical data of the D4x5-2
5.4 Power supply
SIMOTION D4x5-2
Manual, 04/2014 81