Technical Data 10.99
6SE7087-6KP50 Siemens AG
11-6 Operating Instructions SIMOVERT MASTERDRIVES
The derating of the permissible rated current for installation altitudes of
over 1000 m and at ambient temperatures below 45 °C is calculated as
follows:
Total derating = Derating
altitude
x Derating
ambient temperature
K = K
1
x K
2
It must be borne in mind that total derating must not be greater than 1!
Example: Altitude: 3000 m K
1
= 0.845
Ambient temperature: 35 °C K
2
= 1.25
Total derating = 0.845 x 1.25 = 1.056 (= 1)
Year of manufacture
Month of manufacture
Unit designation
List of unit options
Technology functions
released,
if cross is entered here
Fig. 11-2 Rating plate
The date of manufacture can be derived as follows:
Character Year of manufacture: Character Month of manufacture
J
K
L
M
1997
1998
1999
2000
1 to 9
O
N
D
January to September
October
November
December
Table 11-4 Assignment of characters to the month and year of manufacture
NOTE
Rating plate
Date of manufacture

Other manuals for Siemens simovert masterdrives

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens simovert masterdrives and is the answer not in the manual?

Siemens simovert masterdrives Specifications

General IconGeneral
BrandSiemens
Modelsimovert masterdrives
CategoryDC Drives
LanguageEnglish

Related product manuals