Creating the drive project ONLINE
3.5 Operating the drive with the control panel
Getting Started
26 Function Manual, 10/2008, 6SL3097-4AG10-0BP0
5. The " n =" (speed) field is now active. Enter the speed in the now active n=...... field and
confirm this by choosing Enter. If the speed is preceded by a minus sign, the direction of
rotation of the motor is reversed.
Figure 3-17 Setting the speed
6. You can now start the motor by choosing the green l button!
If you press the red O button, the motor stops again. You can use the slider to the right of
the "n =" field to set the speed during operation to between 0% and 200%.
When you click the red/green JOG button, the motor runs at the specified speed for as
long as you keep the mouse button depressed.
To switch off the drive, choose the red O button. The drive comes to a standstill. To return
control priority, choose Return control priority!. The system asks if you are sure you want to
return control priority. Confirm this query to return control priority.