How to resolve 'Line phase failure' on Siemens Control Unit?
- LlisajenningsSep 2, 2025
To address a line phase failure on your Siemens Control Unit, check the converter's input fuses and inspect the motor cables.
How to resolve 'Line phase failure' on Siemens Control Unit?
To address a line phase failure on your Siemens Control Unit, check the converter's input fuses and inspect the motor cables.
What should I check if my Siemens SINAMICS G120D displays 'Motor overtemperature'?
If your Siemens Media Converter indicates a motor overtemperature, you should reduce the motor load, verify the ambient temperature, and inspect the wiring and connection of the temperature sensor.
What to do if Siemens Control Unit displays 'Write task for parameter rejected'?
If your Siemens Control Unit displays 'Write task for parameter rejected', the converter should be reset to the factory setting. However, resetting the safety functions is not allowed because they are currently enabled. Remedy with operator panel: p0010 = 30, Parameter reset; p9761 = …, Enter password for the safety functions; p0970 = 5, Reset Start Safety Parameter. The converter sets p0970 = 5 if it has reset the parameters. Then reset the converter to the factory setting again.
What should I do if my Siemens Media Converter says 'PROFIBUS: Cyclic connection interrupt'?
If your Siemens Media Converter shows 'PROFIBUS: Cyclic connection interrupt', you should establish the PROFIBUS connection and activate the PROFIBUS master with cyclic operation.
What to do if Siemens Media Converter displays 'STOP cam approached with the incorrect traversing direction'?
If your Siemens Media Converter displays 'STOP cam approached with the incorrect traversing direction', check the wiring of the STOP cam.
What to do if Siemens Control Unit displays 'Torque/speed too low'?
If your Siemens Control Unit displays 'Torque/speed too low', check the connection between the motor and the load. Adapt the parameterization corresponding to the load.
How do I troubleshoot F01122 fault on a Siemens SINAMICS G120D?
To resolve the F01122 fault on your Siemens Media Converter, reduce the frequency of the pulses at the probe input.
How to resolve 'Send configuration data not valid' on Siemens Control Unit?
To resolve 'Send configuration data not valid' on your Siemens Control Unit, check the PROFINET configuration.
What should I do if my Siemens SINAMICS G120D displays 'STOP A Triggered'?
If your Siemens Media Converter displays 'STOP A Triggered', select STO and then deselect it again.
What to do if Siemens SINAMICS G120D shows F30004 error?
To troubleshoot the F30004 fault on your Siemens Media Converter, start by checking if the converter fan is running and ensure the ambient temperature is within the allowed range. Also, verify that the motor isn't overloaded and consider reducing the pulse frequency.
Brand | Siemens |
---|---|
Model | SINAMICS G120D |
Category | Media Converter |
Language | English |
Essential safety guidelines for operating electrical devices and preventing hazards.
Provides essential guidelines for electrical connections, including line supplies and EMC rules.
Outlines the steps for performing basic commissioning using the STARTER software tool.
Details the setup and function of the fail-safe digital input for STO safety.
Covers communication setup, functions, and requirements for PROFINET integration.
Details requirements, integration, and configuration for PROFIBUS communication.
Explains how to switch the motor on/off and manage converter states and commands.
Describes the EPOS function, operating modes, commissioning, and configuration of positioning.
Explains the STO safety function, its principle of operation, and commissioning procedures.
Details how the inverter signals faults, the fault buffer, and how to acknowledge and delete faults.
Details recommended procedures for testing safety functions and documenting results.