Setting functions
8.6 Basic positioner and position control
Converter with control units CU250D-2
Operating Instructions, 04/2014, FW V4.7, A5E34261542B AA
203
Direct setpoint input (MDI)
Description
For direct setpoint input (MDI, Manual Data Input), a higher-level control provides the
converter with the position setpoint and traversing profile.
The higher-level control specifies the value of the setpoint either as a relative or an absolute
position setpoint:
Figure 8-38 Axis with direct setpoint input (MDI) positioning
The higher-level control selects the mode "Set-up":
Figure 8-39 Set up axis with direct setpoint input (MDI)