Setting functions
8.6 Basic positioner and position control
Converter with control units CU250D-2
186 Operating Instructions, 04/2014, FW V4.7, A5E34261542B AA
Incremental jogging
Description
In the case of incremental jogging, input a relative traversing distance and a velocity setpoint
into the converter. With the signals "Jogging 1" or "Jogging 2" the converter positions the
axis by the respective travel path.
Figure 8-34 Incremental jogging
Setting jogging
Precondition
You have selected the "Jog" screen.
To set the "jog" function, proceed as follows:
1. Interconnect the signal that defines the mode for the "jog" function.
0: Velocity jogging
1: Incremental jogging
2. Interconnect the signal for jogging 1.
3. Interconnect the signal for jogging 2.
4. Select the button for the other settings.
5. Set the velocities for the "jogging 1" function.
6. Set the velocities for the "jogging 2" function.