Getting Started
Function Manual, 10/2008, 6SL3097-4AG10-0BP0
13
Requirements
2
2.1 Hardware and software components
The example provided here involves creating a drive train with an SMI motor.
The following components are required:
Control Unit CU305
Power Module
SMI motor (synchronous or induction motor)
DRIVE-CLiQ cable
Motor/power cables, optional line filter and line reactor for the Power Module
The following is also required for commissioning:
The components are fully wired.
STARTER commissioning tool as of firmware version 4.1 SP2 with the SINAMICS
Support Package (SSP) SINAMICS_S110_V4.1 installed on the PG/PC.
A null modem cable for establishing a PPI connection between the Control Unit and
PG/PC (RS232).
Note
For detailed information about wiring, the PG/PC, and installing the STARTER
commissioning tool, refer to the S110 Equipment Manual and S110 Function Manual.
Wiring the drive unit
Wire the components (see the following diagram) as described in the S110 Equipment
Manual and S110 Function Manual.
Note
The sections "Line-side power components" and "Cabinet design and EMC" in the S110
Equipment Manual describe the installation and wiring procedures.