Requirements
Data Backup of SINAMICS S120
SINAMICS S120 at Technology CPU Entry ID: 21767896
V1.0 Edition 10/28/05 26/58
Copyright © Siemens AG 2005 All rights reserved
SINAMICS S120 und Technologie-CPU V2.0-SP1__05-10-28_13-20_e.doc
No. Instruction Note
2.
Via the context menu of the CU320
control unit, call the Expert list of
the parameters of SINAMICS S120.
3.
In the expert list, select parameter
p977.
4.
Click in the input box for the
parameter value to call the list for
the input options.
Select the desired backup file 10,
11 or 12.
5.
Acknowledge your selection with
the enter key. The data backup is
started and the text Saves all
parameters as option is displayed
in the parameter field.
The data backup is completed as
soon as the text Not active (0) is
displayed in the parameter field.