EasyManua.ls Logo

Siemens SINUMERIK 810DE - Page 23

Siemens SINUMERIK 810DE
622 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-23
Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
11.02 1 Alarms
2193 "Safety Integrated" is not available for link axis %1.
Parameters: %1 = Machine axis index
Definitions: The "Safety Integrated" function is not available for a link axis. Only occurs with the NCU
link system
Reactions: - Alarm display.
- Interface signals are set.
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
Remedy: Use "Safety Integrated" function for local axes only.
Program Continuation: Switch control OFF - ON.
2195 Channel %1 axis %2 high-speed punching/nibbling not possible via link
Parameters: %1 = Channel number
%2 = Axis name, spindle number
Definitions: An attempt was made to activate high-speed nibbling or punching for an axis programmed
on a different NCU than the drive.
Reactions: - Mode group not ready.
- Channel not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
- Alarm display.
- Interface signals are set.
Remedy: High-speed nibbling and punching is only supported on one NCU.
Program Continuation: Clear alarm with the RESET key in all channels of this mode group. Restart part program.
2196 Link axis active and $MN_MM_SERVO_FIFO_SIZE != %1
Parameters: %1 = required value in MD $MN_MM_SERVO_FIFO_SIZE
Definitions: Occurs only with an NCU link system.
Possible causes of the fault:
At least one axis is to be distributed via NCU link, then the machine data
$MN_MM_SERVO_FIFO_SIZE must be 3 or 4.
The IPO cycle of this NCU is faster than the link communication cycle, then the machine
data $MN_MM_SERVO_FIFO_SIZE must be set to the value proposed in the alarm.
Reactions: - Alarm display.
- Interface signals are set.
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
Remedy: The machine data $MN_MM_SERVO_FIFO_SIZE must be set to the value proposed in
the alarm.
Program Continuation: Switch control OFF - ON.
2900 Reboot is delayed
Definitions: This alarm indicates a delayed reboot.
This alarm only occurs when reboot was carried out by the MMC via PI - "_N_IBN_SS"
and MD $MN_REBOOT_DELAY_TIME was set greater than zero.
The alarm can be suppressed with $MN_SUPPRESS_ALARM_MASK BIT 19.