1-35
Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
11.02 1 Alarms
Reactions: - Alarm display.
- Interface signals are set.
- NC not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
Remedy: Correct the machine data $MC_AXCONF_MACHAX_USED or assign a master channel.
In the event of a link communication failure, these error causes have to be remedied first.
Program Continuation: Switch control OFF - ON.
4032 Channel %1 wrong identifier for facing axis in %2
Parameters: %1 = Channel number
%2 = String: MD identifier
Definitions: According to the axis configuration in $MC_GCODE_RESET_VALUES or
$MC_DIAMETER_AX_DEF, a facing axis identifier is expected at the specified location.
Reactions: - Alarm display.
- Interface signals are set.
- Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Add the correct identifier.
Program Continuation: Switch control OFF - ON.
4033 Notice: NCU link communication still not connected
Definitions: The NCU link communication could not be established due to other active alarms. This is
the case, for example, if during boot-up the system detects and modifies incorrect cycle
times (see alarm 4110).
Reactions: - Alarm display.
- Interface signals are set.
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
Remedy: Analyze and fix the other alarms and start the control again.
Program Continuation: Switch control OFF - ON.
4034 Local link axis %1 is not allowed for different interpolation cycle time = %2/%3
Parameters: %1 = Axis name
%2 = Local interpolation cycle
%3 = Max. interpolation cycle
Definitions: Local link axes are only permissible on an NCU if the interpolation cycle set corresponds
to the slowest interpolation cycle of the interconnected NCU systems.
Reactions: - Alarm display.
- Interface signals are set.
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
Remedy: Remove local link axis (see MN_AXCONF_MACHAX_NAME_TAB and
MN_AXCT_AXCONF_ASSIGN_TAB1) or adapt the interpolation cycle
(MN_IPO_SYSCLOCK_TIME_RATIO).
Program Continuation: Switch control OFF - ON.