EasyManua.ls Logo

Siemens SINUMERIK 810DE - Page 37

Siemens SINUMERIK 810DE
622 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-37
Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
11.02 1 Alarms
Reactions: - Alarm display.
- Interface signals are set.
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Check and correct the identi-
fier used in the MDs 10000 AXCONF_MACHAX_NAME_TAB, 20080
AXCONF_CHANAX_NAME_TAB and/or 20050 AXCONF_GEOAX_NAME_TAB.
Only with active "OEM transformation" compile cycle: In addition to the specified MD,
check and correct MD 24110 TRAFO_AXES_IN_1[n] of the activated OEM transforma-
tion according to the function description.
Program Continuation: Switch control OFF - ON.
4045 Channel %1 conflict between machine data %2 and machine data %3
Parameters: %1 = Channel number
%2 = String: MD identifier
%3 = String: MD identifier
Definitions: Using the specified machine data %2 leads to a conflict with machine data %3.
Reactions: - NC not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Mode group not ready, also effective for single axes
Remedy: Correct the specified machine data.
Program Continuation: Switch control OFF - ON.
4050 NC code identifier %1 cannot be reconfigured to %2
Parameters: %1 = String: Old identifier
%2 = String: New identifier
Definitions: Renaming of an NC code was not possible for one of the following reasons:
The old identifier does not exist
The new identifier is within another type range.
NC codes/keywords can be reconfigured as long as you stay within the type range.
Type 1: "true" G codes: G02, G17, G33, G64, ...
Type 2: named G codes: ASPLINE, BRISK, TRANS, ...
Type 3: addresses which can be set: X, Y, A1, A2, I, J, K, ALF, MEAS, ...
Reactions: - Alarm display.
- Interface signals are set.
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Correct machine data 10712:
NC_USER_CODE_CONF_NAME_TAB (protection level 1).
The list must be built up as follows:
Even address: Identifier to be modified Following odd address: New identifier
e.g.: NC_USER_CODE_CONF_NAME_TAB [10] = "ROT",
NC_USER_CODE_CONF_NAME_TAB [11] = " " clears the ROT function from the control
Program Continuation: Switch control OFF - ON.

Other manuals for Siemens SINUMERIK 810DE

Related product manuals