1 Alarms 11.02
1-48
Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
4215 Channel %1 spindle %2 declaration as modulo axis missing
Parameters: %1 = Channel number
%2 = Axis name, spindle number
Definitions: The spindle functionality requires a modulo axis (positions in [deg],.).
Reactions: - Mode group not ready.
- Channel not ready.
- NC Stop on alarm.
- NC Start disable in this channel.
- Alarm display.
- Interface signals are set.
Remedy: Please inform the authorized personnel/service department. Set MD
"ROT_IS_MODULO".
Program Continuation: Switch control OFF - ON.
4220 Channel %1 spindle %2 declared repeatedly
Parameters: %1 = Channel number
%2 = Axis name, spindle number
Definitions: The spindle number exists more than once in the channel.
Reactions: - Alarm display.
- Interface signals are set.
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. The spindle number is stored
in the axis-specific MD array 35000 SPIND_ASSIGN_TO_MACHAX. The channel to
which this machine axis/spindle is assigned is listed in the machine axis index. (The
machine axis number is given in the channel-specific MD array 20070
AXCONF_MACHAX_USED).
Program Continuation: Switch control OFF - ON.
4225 Channel %1 axis %2 declaration as rotary axis missing
Parameters: %1 = Channel number
%2 = Axis name, axis number
Definitions: The modulo functionality requires a rotary axis (positions in [deg],.).
Reactions: - Mode group not ready.
- Channel not ready.
- NC Stop on alarm.
- NC Start disable in this channel.
- Alarm display.
- Interface signals are set.
Remedy: Please inform the authorized personnel/service department. Set MD "IS_ROT_AX".
Program Continuation: Switch control OFF - ON.
4230 Channel %1 data alteration from external not possible in current channel state
Parameters: %1 = Channel number
Definitions: It is not allowed to enter this data while the part program is being executed (e.g. setting
data for working area limitation or for dry run feedrate).
Reactions: - Alarm display.
Remedy: The data to be entered must be altered before starting the part program.
Program Continuation: Clear alarm with the Delete key or NC START.