Overview of Alarms 08/2005
2-32
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
• 47: New-Config active
Reactions: - Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: The program must be canceled with Reset and the zero offset deselected before activat-
ing the axis container switch.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
4020 Identifier %1 used several times in machine data %2
Parameters: %1 = String: Name of identifier
%2 = String: MD identifier
Definitions: When determining a name in the NCK tables (arrays) for: machine axes, Euler angles,
Richtungsvektoren, direction vectors, interpolation parameters and intermediate point
coordinates, an identifier has been used that is already in the control.
Reactions: - NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Select for the identifier to be
entered a character string that is not yet used in the system (max. 32 characters).
Program Con-
tinuation:
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
4021 Channel %1 identifier %2 used several times in machine data %3
Parameters: %1 = Channel number
%2 = String: Name of identifier
%3 = String: MD identifier
Definitions: To determine the name in the channel-specific tables for geometry axes and channel
axes an identifier already existing in the control has been used.
Reactions: - NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Select for the identifier to be
entered a character string that is not yet used in the system (max. 32 characters).
Program Con-
tinuation:
Switch control OFF - ON.
4022 Axis container %3 switch not allowed: ext. zero offset active channel %1 axis %2
Parameters: %1 = Channel
%2 = Axis/spindle
%3 = Axis container number
Definitions: The axis container switch enable cannot be given because an external zero offset is
active.