08/2005 Overview of Alarms
2-33
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Reactions: - Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: The program must be aborted with the RESET key and the external zero point offset
deselected before the container is advanced.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
4023 Axis container %1 switch not allowed, axis container %2 switch active
Parameters: %1 = Axis container
%2 = Axis container
Definitions: Only one axis container can be rotated at a time.
Reactions: - Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Program must be canceled with Reset and the program sequences (NCUs, channels)
must be synchronized such that only one axis container switch is active at a time.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
4024 Invalid axis configuration due to missing axis container machine data
Parameters: %1 = NCU number
%2 = Axis container number
Definitions: The axis configuration could not be generated due to missing axis container machine
data. This error can only occur as a result of a communication error. The communication
failure will be indicated separately by further alarms.
Reactions: - NC not ready.
- Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Correct the link communication problems (refer to the other alarm messages).
Program Con-
tinuation:
Switch control OFF - ON.
4025 Axis container %3 switch not allowed: master/slave active channel %1 axis %2
Parameters: %1 = Channel
%2 = Axis/spindle
%3 = Axis container number
Definitions: It is not possible to enable axis container switch as a master/slave link is active.
Reactions: - Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.