Remedy: Abort program with the RESET key. If required, disconnect the master - slave coupling.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
4026 Machine data %1[%2], link axis NC%3_AX%4 not used by any channel
Parameters: %1 = String: MD identifier
%2 = Index: MD array
%3 = NCU number
%4 = Machine axis number
Definitions: The link axis is not referenced by any channel.
Reactions: - NC not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Correct and complete the logical axis assignments. Check machine data
MC_AXCONF_MACHAX_USED and MN_AXCONF_LOGIC_MACHAX_TAB.
Program Con-
tinuation:
Switch control OFF - ON.
4027 Caution: MD %1 was also changed for the other axes of axis container %2
Parameters: %1 = String: MD identifier
%2 = Axis container number
Definitions: Message to the user indicating that the machine data change for the axis was also per-
formed for all other axes in the same container.
Reactions: - Alarm display.
Remedy: None
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
4028 Attention! The axial MDs of the axes of the axis containers were matched.
Definitions: Note for the user, that the machine data of the axis were matched in the axis containers.
Reactions: - Alarm display.
Remedy: None
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
4029 Caution: the axial MDs in axis container %1 will be matched on the next power-up
Parameters: %1 = Axis container number
Definitions: Message to the user indicating that the machine data of the axes in the axis container will
be matched on the next power-up. An axis container allows axes to be exchanged
between channels and NCUs. To ensure that no conflicts arise, the axes within the same
axis container must have a similar behavior. The first axis in the axis container determines
which machine data have to be the same for the other axis in the axis container.
Reactions: - Alarm display.
Remedy: None
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
4030 Channel %1 axis identifier missing in machine data %2[%3]
Parameters: %1 = Channel number