EasyManuals Logo

Siemens SINUMERIK 840D sl Series User Manual

Siemens SINUMERIK 840D sl Series
1002 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #35 background imageLoading...
Page #35 background image
08/2005 Overview of Alarms
2-35
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
%2 = String: MD identifier
%3 = Index: MD array
Definitions: An axis identifier is expected for the displayed MD in accordance with the axis configura-
tion in the MD 20070 AXCONF_MACHAX_USED and 20050
AXCONF_GEOAX_ASSIGN_TAB.
Reactions: - NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Check axis configuration and
enter the missing identifier into the MD or, should the axis not exist, specify for this chan-
nel axis the machine axis 0 in the channel-specific MD 20070
AXCONF_MACHAX_USED. If this concerns a geometry axis that is not to be used (this
applies only for 2-axis machining, e.g. on lathes), then channel axis 0 must be entered
additionally in the channel-specific MD 20050 AXCONF_GEOAX_ASSIGN_TAB.
Program Con-
tinuation:
Switch control OFF - ON.
4031 Channel %1 link axis %2 defined for more than one channel in machine data %3
Parameters: %1 = Channel number
%2 = Index: Axis number for logical axis assignment
%3 = String: MD identifier
Definitions: Occurs only with an NCU link system. The specified axis was defined several times or in
several channels in machine data $MC_AXCONF_MACHAX_USED. If an axis is to be
defined in several channels, a master channel must be assigned to the axis with the axial
machine data $MA_AXCONF_ASSIGN_MASTER_CHAN. This error can only occur with
an NCU link axis. The cause of a definition error can also be an NCU link communication
failure. The link communication failure must be indicated separately by further alarms.
Reactions: - NC not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Correct the machine data $MC_AXCONF_MACHAX_USED or assign a master channel.
In the event of a link communication failure, these error causes have to be remedied first.
Program Con-
tinuation:
Switch control OFF - ON.
4032 Channel %1 wrong identifier for facing axis in %2
Parameters: %1 = Channel number
%2 = String: MD identifier
Definitions: According to the axis configuration in $MC_GCODE_RESET_VALUES or
$MC_DIAMETER_AX_DEF, a facing axis identifier is expected at the specified location.
Reactions: - Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Add the correct identifier.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D sl Series and is the answer not in the manual?

Siemens SINUMERIK 840D sl Series Specifications

General IconGeneral
Control TypeCNC
PLCIntegrated SIMATIC S7-300
InterfacesEthernet, PROFIBUS, PROFINET, USB
Max Axes31
Programming LanguagesDIN/ISO 66025, high-level language (C/C++), Siemens programming languages (e.g., ShopMill, ShopTurn)
Safety FeaturesIntegrated safety functions (Safety Integrated)
Operating SystemWindows-based
Drive InterfaceSINAMICS S120
ApplicationsMilling, turning, grinding, laser
DisplayTFT color display, various sizes