EasyManuals Logo

Siemens SINUMERIK 840D sl Series User Manual

Siemens SINUMERIK 840D sl Series
1002 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #36 background imageLoading...
Page #36 background image
Overview of Alarms 08/2005
2-36
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Program Con-
tinuation:
Switch control OFF - ON.
4033 Caution: NCU link communication still not connected
Definitions: The NCU link communication could not be established due to other active alarms. This is
the case, for example, if during boot-up the system detects and modifies incorrect cycle
times (see alarm 4110).
Reactions: - NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Analyze and fix the other alarms and start the control again.
Program Con-
tinuation:
Switch control OFF - ON.
4034 Local link axis %1 is not allowed for different interpolation cycle time = %2/%3
Parameters: %1 = Axis name
%2 = Local interpolation cycle
%3 = Max. interpolation cycle
Definitions: Local link axes are only permissible on an NCU if the interpolation cycle set corresponds
to the slowest interpolation cycle of the interconnected NCU systems.
Reactions: - NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Remove local link axis (see MN_AXCONF_MACHAX_NAME_TAB and
MN_AXCT_AXCONF_ASSIGN_TAB1) or adapt the interpolation cycle
(MN_IPO_SYSCLOCK_TIME_RATIO).
Program Con-
tinuation:
Switch control OFF - ON.
4035 Interpolation cycle from NCU%1 = %2 does not match NCU%3 = %4
Parameters: %1 = NCU_number1
%2 = MD value of NCU_number1
%3 = NCU_number2 (with slowest IPO cycle)
%4 = MD value of NCU_number2
Definitions: Occurs only with an NCU link system. The interpolation cycles of the NCUs specified in
the alarm do not match one another. The slowest IPO cycle in interconnected NCU sys-
tems must be an integral multiple of all configured IPO cycles.
Reactions: - NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Set a suitable value in MN_IPO_SYSCLOCK_TIME_RATIO for all interconnected NCUs.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D sl Series and is the answer not in the manual?

Siemens SINUMERIK 840D sl Series Specifications

General IconGeneral
Control TypeCNC
PLCIntegrated SIMATIC S7-300
InterfacesEthernet, PROFIBUS, PROFINET, USB
Max Axes31
Programming LanguagesDIN/ISO 66025, high-level language (C/C++), Siemens programming languages (e.g., ShopMill, ShopTurn)
Safety FeaturesIntegrated safety functions (Safety Integrated)
Operating SystemWindows-based
Drive InterfaceSINAMICS S120
ApplicationsMilling, turning, grinding, laser
DisplayTFT color display, various sizes

Related product manuals