08/2005 Overview of Alarms
2-47
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Definitions: In the specified machine data, a number has been specified for the configuration of an M
function which is occupied by the system, and cannot be used for an assignment. (M0 to
M5, M17, M30, M40 to M45 and also M98, M99 with applied ISO dialect). The value set
by the user has been reset to the default value by the system.
Reactions: - Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Configure an M function in the specified machine data which is not occupied by the sys-
tem (M0 to M5, M17, M30, M40 to M45 and also M98, M99 with applied ISO dialect).
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
4183 Channel %1 M auxiliary function number %2 used several times (%3 and %4)
Parameters: %1 = Channel number
%2 = M auxiliary function number
%3 = MD identifier
%4 = MD identifier
Definitions: In the specified machine data, a number has been used several times for the configura-
tion of an M function.
Reactions: - Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Check the specified machine data and create a unique assignment of M auxiliary function
numbers.
Program Con-
tinuation:
Switch control OFF - ON.
4184 Channel %1 illegally predefined auxiliary function in %2%3, MD reset
Parameters: %1 = Channel number
%2 = MD identifier
%3 = If required, MD index
Definitions: In the specified machine data, a predefined auxiliary function has been illegally config-
ured.
The value set by the user has been reset to the default value by the system.
Reactions: - Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Configure a valid value in the specified machine data.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
4185 Channel %1 illegal auxiliary function configured %2 %3 %4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D sl Series and is the answer not in the manual?

Siemens SINUMERIK 840D sl Series Specifications

General IconGeneral
Control TypeCNC
PLCIntegrated SIMATIC S7-300
InterfacesEthernet, PROFIBUS, PROFINET, USB
Max Axes31
Programming LanguagesDIN/ISO 66025, high-level language (C/C++), Siemens programming languages (e.g., ShopMill, ShopTurn)
Safety FeaturesIntegrated safety functions (Safety Integrated)
Operating SystemWindows-based
Drive InterfaceSINAMICS S120
ApplicationsMilling, turning, grinding, laser
DisplayTFT color display, various sizes

Related product manuals