List of Action Numbers 08/2005
3-952
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
No. 12
No. 13
No. 14
No. 15
No. 16
Explanation Perform a user interrupt at the end of the block (VDI signal: ASUB interface, digital-ana-
log interface).
Not allowed if See 10
Remedy -
Explanation Perform a rapid retraction (VDI signal: Digital-analog interface and ASUB interface, for
further actions see 10, 11, 12, 85, 86).
Not allowed if -
Remedy -
Explanation Move tool - only with tool management (PI command).
Not allowed if -
Remedy -
Explanation Perform deletion of distance-to-go or axis synchronization (VDI signal: deletion of dis-
tance-to-go or follow-up mode) (follow-up mode: e.g. on activation of axis motion).
Not allowed if 1. nesting depth too great
2. the active block, after which deceleration takes place, cannot be reorganized (occurs
when deceleration takes place over several blocks).
Remedy Abort program
Explanation Abort repetition of subroutine (VDI signal: Delete number of subroutine repetitions).
Not allowed if 1. Nesting depth too great
2. the active block, after which deceleration takes place, cannot be reorganized (occurs
when deceleration takes place over several blocks).
Remedy Abort program