List of Action Numbers 08/2005
3-962
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
No. 63
No. 64
No. 65
No. 66
No. 67
Explanation Activate test run (VDI signal: Rapid traverse override)
Not allowed if 1. Nesting depth too great
2. the active block, after which deceleration takes place, cannot be reorganized (occurs
when deceleration takes place over several blocks).
Remedy − Wait until the preceding ASUB is complete or abort the program.
− Abort program
Explanation Deactivate test run (VDI signal: Rapid traverse override)
Not allowed if 1. Nesting depth too great
2. the active block, after which deceleration takes place, cannot be reorganized (occurs
when deceleration takes place over several blocks).
Remedy − Wait until the preceding ASUB is complete or abort the program.
− Abort program
Explanation Activate read-in disable for main run block (VDI signal: Read-in disable).
Not allowed if -
Remedy -
Explanation Deactivate read-in disable for main run block (VDI signal: Read-in disable).
Not allowed if -
Remedy -
Explanation Stop at block end (alarm)
Not allowed if -
Remedy -