08/2005 List of Action Numbers
3-969
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
No. 100
No. 101
No. 102
No. 103
No. 104
Explanation Integrated block search, i.e., a block search is restarted on a stopped program.
Not allowed if -
Remedy -
Explanation External zero offset is activated via the PLC. Movement is stopped, a Reorg is per-
formed, the interpreter is switched over and then selected using REPOS and continued
automatically.
Not allowed if 1. The channel is not in AUTO or MDI
2. The channel is stopped and the current block cannot be reorganized.
Remedy − Select Auto or MDI
− Activate a block change until the NC block can be reorganized.
Explanation Single block type 3 is activated. With single block type 3, a stop is performed at all main
blocks. Unlike single block type 1, the part program command SBLOF is ignored.
Not allowed if -
Remedy -
Explanation Stopping of a single axis movement (VDI signal)
Not allowed if The axis is not controlled by the PLC (exception old reaction with oscillation axis).
Remedy -
Explanation Stopping of a single axis movement by an alarm
Not allowed if the axis is not controlled by the PLC. (exception old reaction with oscillation axis).
Remedy -