EasyManua.ls Logo

Siemens SINUMERIK 840D sl - Page 28

Siemens SINUMERIK 840D sl
1002 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Overview of Alarms 08/2005
2-28
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Parameters: %1 = Axis
%2 = String: MD identifier
Definitions: Machine axes which can be activated on several NCKs through
$MN_AXCONF_LOGIC_MACHAX_TAB must be assigned to a master NCU in
$MA_AXCONF_ASSIGN_MASTER_NCU. For axes that are activated on only one NCU,
the number of this NCU or zero must be entered as master NCU. An assignment can only
be made with MA_AXCONF_ASSIGN_MASTER_NCU if the machine axis is also
addressed via a channel
($MC_AXCONF_MACHAX_USED+$MN_AXCONF_LOGIC_MACHAX_TAB).
Reactions: - NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Correct $MA_AXCONF_ASSIGN_MASTER_NCU and/or
$MN_AXCONF_LOGIC_MACHAX_TAB.
Program Con-
tinuation:
Switch control OFF - ON.
4010 Invalid identifier used in machine data %1[%2]
Parameters: %1 = String: MD identifier
%2 = Index: MD array
Definitions: When determining a name in the NCK tables (arrays) for: machine axes, Euler angles,
Richtungsvektoren, direction vectors, interpolation parameters and intermediate point
coordinates, one of the following syntax rules for the identifier to be entered has been vio-
lated:
The identifier must be an NC address letter (A, B, C, I, J, K, U, V, W, X, Y, Z), possibly
with a numerical extension (840D: 1-99, FM-NC: 1-9)
The identifier must begin with 2 arbitrary capital letters but not with $ (reserved for sys-
tem variable).
The identifier must not be a keyword of the NC language (e.g. POSA).
Reactions: - NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Enter the identifier for user-
defined names with correct syntax in the displayed MD.
Machine axes: AXCONF_MACHAX_NAME_TAB
Euler angles: EULER_ANGLE_NAME_TAB
Normal vectors: NORMAL_VECTOR_NAME_TAB
Direction vectors: 10640 DIR_VECTOR_NAME_TAB
Interpolation parameters: 10650 IPO_PARAM_NAME_TAB
Intermediate point coordinates: 10660 INTERMEDIATE_POINT_NAME_TAB
Program Con-
tinuation:
Switch control OFF - ON.
4011 Channel %1 invalid identifier used in machine data %2[%3]
Parameters: %1 = Channel number
%2 = String: MD identifier

Other manuals for Siemens SINUMERIK 840D sl