EasyManua.ls Logo

Siemens SINUMERIK 840D sl - Page 29

Siemens SINUMERIK 840D sl
1002 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
08/2005 Overview of Alarms
2-29
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
%3 = Index: MD array
Definitions: When defining names in the channel-specific tables for geometry axes and channel axes,
one of the following syntax rules for the identifier to be entered has been violated:
The identifier must be an NC address letter (A, B, C, I, J, K, U, V, W, X, Y, Z), possibly
with a numerical extension (840D: 1-99, FM-NC: 1-9).
The identifier must begin with 2 arbitrary capital letters but not with $ (reserved for sys-
tem variable).
The identifier must not be a keyword of the NC language (e.g. POSA).
Reactions: - NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Enter the identifier for user-
defined names with correct syntax in the displayed MD
Geometry axes: 20060 AXCONF_GEOAX_NAME_TAB
Channel axes: 10000 AXCONF_MACHAX_NAME_TAB
Program Con-
tinuation:
Switch control OFF - ON.
4012 Invalid identifier used in machine data %1[%2]
Parameters: %1 = String: MD identifier
%2 = Index: MD array
Definitions: The selected identifier is invalid. Valid identifiers are:
AX1 - AXn: Machine axis identifiers
N1AX1 - NnAXm: Link axis identifiers (NCU + machine axis), only occurs with 'NCU link'
expansion level!
C1S1 - CnSm: Container axis identifiers (container + container location). Only occurs
with 'axis container' expansion level!
Reactions: - NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: Use the correct identifier.
Program Con-
tinuation:
Switch control OFF - ON.
4013 Invalid NCU link configuration by machine data %1 = %2 , on NCU_1 = %3
Parameters: %1 = String: MD identifier
%2 = Index: MD array
%3 = MD value of master NCU
Definitions: The link module configuration detected on the local NCU is different from the master NCU
of the NCU cluster. The link module configuration defines the system clock time, the com-
munication baudrate and the maximum number of message transfer retries.
The following machine data are used for this purpose:
SYSCLOCK_SAMPL_TIME_RATIO,
IPO_SYSCLOCK_TIME_RATIO,
LINK_RETRY_CTR,

Other manuals for Siemens SINUMERIK 840D sl