Overview of Alarms 08/2005
2-86
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Parameters: %1 = String: MD identifier
Definitions: A machine data has been set that is locked by an option.
Reactions: - Alarm display.
Remedy: Please inform the authorized personnel/service department. For retrofitting the option,
please refer to your machine manufacturer or to a sales representative of SIEMENS AG,
A&D MC.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
8041 Axis %1: MD %2 reset, corresponding option not sufficient
Parameters: %1 = Axis number
%2 = String: MD identifier
Definitions: All of the axes selected in the machine data of the assigned option are used. Safety func-
tions have been selected for too many axes in the axial machine data.
The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY
(channel not ready).
Reactions: - Mode group not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
- Channel not ready.
Remedy: --
Program Con-
tinuation:
Switch control OFF - ON.
8044 Option for IPO cycle time %1 ms not set
Parameters: %1 = Impermissible IPO cycle time
Definitions: The option for activation of an IPO cycle time of %1 ms has not been set.
Option - Permiss. IPO cycle time:
Option-free >= 8ms
1. 1st step >= 6ms
2. 2nd step >= 4ms
3. 3rd step >= 2ms
4. 4th step <2ms
Reactions: - Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy: Buy option
Increase IPO cycle time (e.g. via MD IPO_SYSCLOCK_TIME_RATIO)
Program Con-
tinuation:
Switch control OFF - ON.
8045 Option for selected cycle settings not set
Definitions: The option for the 810D Powerline for activation of the same current/speed/position con-
troller/IPO cycle time grid as with the 840D is not set. Without the option, only the set val-
ues of the 810D Standard are permitted.
Reactions: - Interpreter stop
- NC Start disable in this channel.