08/2005 Overview of Alarms
2-85
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
- Interface signals are set.
- Alarm display.
Remedy: • Buy option
• Do not configure any containers
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
8036 Option: it is not allowed to set different IPO cycles or position control cycles with
NCU link.
Definitions: The option for activating the FAST_IPO_LINK has not been set. For NCU link, all Ipo or
position control cycles must then be equal (see FAST-IPO-LINK description).
Reactions: - NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: • Buy option
• Do not activate different Ipo or position control cycles (see
MN_IPO_SYSCLOCK_TIME_RATIO and MN_POSCTRL_SYSCLOCK_TIME_RATIO).
Program Con-
tinuation:
Switch control OFF - ON.
8037 Option 'APC activation' not set
Definitions: Function 'Advanced Positioning Control' (APC) has been activated in the drive, although
the corresponding option was not set.
Reactions: - NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
- NC Stop on alarm.
Remedy: • Buy option
• Deactivate function 'Advanced Positioning Control' (APC) in the drive
Program Con-
tinuation:
Switch control OFF - ON.
8038 Option 'activation of more than %1 lead link axes' not set
Parameters: %1 = Number of axes
Definitions: The option for the number of lead link axes does not match the number of configured axes
in the MD $MA_AXCONF_ASSIGN_MASTER_NCU.
Reactions: - Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy: • Buy option
• Configure fewer lead link axes
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
8040 Machine data %1 reset, corresponding option is not set