Loading...
Overview of Alarms 08/2005
2-84
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Buy option
Activate less SRAM
Program Con-
tinuation:
Switch control OFF - ON.
8023 Option 'Activation of more than %1 KB PLC user memory' not set
Parameters: %1 = Memory size
Definitions: The option for the memory configuration does not correspond to the PLC user memory
used.
Reactions: - NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy: Please inform the authorized personnel/service department.
Purchase option
Use less PLC user memory
Program Con-
tinuation:
Switch control OFF - ON.
8030 Channel %1 block %2 option 'interpolation of more than 4 axes' not set
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The option for the number of interpolating axes does not correspond to the number of
axes programmed in the interpolation group.
Reactions: - Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy: Option: "Interpolation of more than 4 axes" (the number of axes that is then allowed can
be set in this option) or specify in the part program as many (or fewer, as required) axes
corresponding to the configuration of the control.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
8032 Option 'activation of more than %1 link axes' not set
Parameters: %1 = Number of axes
Definitions: The option for the number of link axes does not match the number of axes programmed in
MD $MN_AXCONF_LOGIC_MACHAX_TAB.
Reactions: - Interpreter stop
- NC Start disable in this channel.
- Interface signals are set.
- Alarm display.
Remedy: Buy option
Configure fewer link axes
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
8034 Option 'activation of axis containers' not set
Definitions: The option for activating the axis container function in MD
$MN_AXCONF_LOGIC_MACHAX_TAB is not enabled.
Reactions: - Interpreter stop
- NC Start disable in this channel.

Other manuals for Siemens SINUMERIK 840D sl