08/2005 List of Action Numbers
3-963
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
No. 68
No. 69
No. 70
No. 71
No. 72
Explanation Stop all axes (alarm)
Not allowed if -
Remedy -
Explanation Activate program test (VDI signal: Program test).
Not allowed if Tool management is active.
The NCK channel is in a state other than "ready".
Remedy Backing up tool data
Abort the program or process with the Reset key or wait for end of program.
Explanation Deactivate program test (VDI signal: Program test).
Not allowed if The NCK channel is in a state other than "ready".
Remedy Abort the program or process with the Reset key or wait for end of program.
Explanation Stop at the end of block preparation (alarm)
Not allowed if -
Remedy -
Explanation Stop at the end of block preparation with subsequent reorganization of block processing
(alarm)
Not allowed if Nesting depth too great.
Remedy Wait until the preceding ASUB is complete or abort the program.