No. 73
No. 74
No. 75
No. 76
No. 77
No. 78
Explanation Conditional stop at block end. If, after continuation by means of an NC Start, there is still
a reason to stop "Stop at block end", the program stops again.
Not allowed if -
Remedy -
Explanation Conditional stop at block end. (Despite the start, the interpreter or the preprocessing
does not manage to put a block in main run)
Not allowed if -
Remedy -
Explanation Stop preprocessing (alarm)
Not allowed if -
Remedy -
Explanation Retraction with G33 and Stop
Not allowed if -
Remedy -
Explanation Conditional wait for program marker (NC block: WAITMC).
Not allowed if -
Remedy -
Explanation Set marker (NC block: SETM).
Not allowed if -