11.92 5 Configuring
5.2 FB 111 Neutral tool search
Parameter assignment of the search area
Search key
Tool
size
KEN1
Tool
ID
KEN2
Ident
No.
T No.
Duplo
No.
DUNR
First
UR DB
AW-1
Internal parameter assignment of DW 1
and DW 2 of the magazine table
DB-
151
DB-
151
DB-
153
DB-
154
DB-
155
DB-
156
DB-
157
–x–
%x%%%%%
x x x x%%%%%
–xx%x0xx%%
xxxxx0xx%%
–xxx%x0xxx%
xxxxxx0xxx%
–x–x%x0000x
xxxxx0000x
–xxx%x0xx0x
xxxxxx0xx0x
x x x x %x0xxxx
x x x x x xx0xxxx
with x >< -1 : The parameter is contained in the search key,
- = -1 : The parameter is not contained in the search key,
0 : This part of the search key is masked out (search argument
and search mask = 0),
% : The data block is not contained in the search key (definition of the search
masks).
Definition of the search masks
Search masks are to be specified for the parameters
KEN2 = Tool identifications and
AW-1 = First user DB of the user list
only.
The parameters
KEN1 is assigned to mask MAS1 (internal data transfer interface)
KEN2 is assigned to mask MAS2 and parameter
AW-1 to mask AWM1
For the remaining parameters
T-NR =ID No. as well as
DUNR = Duplo-Nr.
the masks are preset internally with FFFFh.
If a search key extends beyond the reference data block (DB 153), this reference data block is
always masked out in the search key.
© Siemens AG 1991 All Rights Reserved 6FC5 197-0AA40-1BP1 5–7