V24 setting Meaning
Wait for XON for start re‐
ceive V24
Only with protocol: Xon/Xoff
End of data transfer (hex) Only for punched tape format
Stop with end of data transfer character
The default setting for the end of data transfer character is (HEX) 1A
Time monitoring (sec) Time monitoring
For data transfer problems or at the end of data transfer (without end of
data transfer character) data transfer is interrupted after the specified
number of seconds.
The time monitoring is controlled by a time generator (clock) that is star‐
ted with the first character and is reset with each transferred character.
The time monitoring can be set (seconds).
Procedure
1. Select the "Program Manager" operating area.
2. Press softkey "NC" or "Local Drive".
3. Press the ">>" and "Archive" softkeys.
4. Select the "V24 settings" softkey.
Window "Interface: V24" is opened.
5. The interface settings are displayed.
6. Press the "Details" softkey if you wish to view and process addi‐
tional settings for the interface.
Managing programs
14.19 RS-232-C
Milling
804 Operating Manual, 08/2018, 6FC5398-7CP41-0BA0

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals