EasyManua.ls Logo

Siemens SITRANS FM MAG 5000

Siemens SITRANS FM MAG 5000
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
SITRANS F
Electromagnetic flowmeters
SITRANS FM MAG 5000/6000 IP67
Operating Instructions
7ME6910 (SITRANS MAG 5000)
7ME6920 (SITRANS MAG 6000)
12/2019
A5E02338368-AD
Introduction
1
Safety notes
2
Description
3
Installing/Mounting
4
Connecting
5
Commissioning
6
Operating
7
Service and maintenance
8
Diagnostics and
Troubleshooting
9
Technical data
10
Spare parts/Accessories
A
Menu diagrams
B
Factory settings
C
Product documentation and
support
D

Table of Contents

Questions and Answers:

Siemens SITRANS FM MAG 5000 Specifications

General IconGeneral
BrandSiemens
ModelSITRANS FM MAG 5000
CategoryTransmitter
LanguageEnglish

Summary

Legal Information

Warning Notice System

Explains the manual's warning notice system and hazard grading.

Qualified Personnel

Defines qualified personnel responsible for operating the device.

Proper Use of Siemens Products

Notes on using Siemens products safely and correctly.

Trademarks

Lists registered and common trademarks used in the publication.

Disclaimer of Liability

States consistency check and rights for technical changes.

Introduction

Purpose of Documentation

Explains the manual's content, target audience, and principle of operation.

Document History

Lists previous document editions and their major changes.

Checking the Consignment

Instructions for verifying delivery contents for damages and completeness.

Items Supplied

Lists all components included in the product package.

Security Information

Provides guidance on industrial security and cyber threat prevention.

Transportation and Storage

Guidelines for ensuring product protection during transport and storage.

Notes on Warranty

Clarifies that the manual does not modify warranty conditions.

Safety Notes

Laws and Directives

Covers general installation requirements and instrument safety standards.

Environmental Conditions

Specifies environmental conditions according to IEC 61010-1 for device operation.

Conformity with European Directives

Lists European directives (EMC, LVD, ATEX) the device conforms to.

Installation in Hazardous Location

Details conditions for safe use and Ex approvals for hazardous areas.

EX Requirements

Lists specific requirements for electrical connections and installation in hazardous areas.

Description

System Components

Lists the main components of the SITRANS F M MAG 5000/6000 flowmeter system.

Operating Principle

Explains the flow measurement principle based on Faraday's law.

Applications

Lists sectors and industries where the flowmeters are suitable for use.

Features

Describes key features such as power supply, dialog, and output modules.

MAG 5000 MAG 6000 Versions

Details the different available versions of the MAG 5000 and MAG 6000 transmitters.

Nameplate Layout

Explains how to read and interpret the information on the device's nameplate.

InstallingMounting

Introduction

States suitability for indoor/outdoor installations and chapter scope.

Installation Conditions

Discusses factors affecting optimum flow measurement like orientation and vibrations.

MAG 50006000 Compact

Step-by-step guide for installing the compact version of the flowmeter.

Remote Installation

Detailed instructions for mounting the transmitter and sensor in a remote configuration.

MAG 50006000 CT

Information on installing the CT version, including calibration sealing.

Turning TransmitterKeypad

Instructions on orienting the transmitter and keypad for optimal viewing.

Connecting

Electrical Connection

Detailed wiring diagram and instructions for connecting power, outputs, and sensors.

Electrical Connection PTB K7.2

Additional connection details for PTB K7.2 approved models.

Connection of Add-on Modules

Information on connecting add-on communication modules.

Commissioning

MAG 50006000 Blind Commissioning

Instructions for commissioning the blind version using a standard transmitter.

Local User Interface

Explains symbols and fields of the device's local user interface.

Menu Structure

Outlines the structure of the operator and setup menus.

Changing Password

Step-by-step guide to change the password for setup menus.

Changing Basic Settings

Details parameters configurable in the basic settings menu.

Changing Operator Menu Setup

How to customize visible menus in the operator menu.

Changing Language

Instructions for changing the transmitter's display language.

Operating

Output Settings

Explains configuration options for current, digital, and relay outputs.

External Input Functions

Describes using external digital inputs for control and totalizer functions.

Sensor Characteristics

Details parameters for sensor configuration and calibration.

Reset Mode

Explains how to reset totalizers or restore factory settings.

Service Mode

How to use service mode for checking outputs and logs.

MAG 5000 CT and MAG 6000 CT Settings

Configuration settings specific to CT versions, including totalizers.

MAG 6000 SV Excitation Frequency

Information on adjusting excitation frequency for MAG 6000 SV.

Service and Maintenance

Transmitter Check List

Provides a checklist for verifying transmitter status and operation.

Technical Support

Contact information and resources for technical assistance.

Return Procedure

Steps and forms for returning a device for service or repair.

Recalibration

Information on Siemens AG's recalibration service for sensors.

Diagnostics and Troubleshooting

Diagnostics

Explains the error system, acceptance levels, and error logging.

List of Error Numbers

A comprehensive list of error codes, their meanings, and remedies.

Technical Data

Technical Specifications

Detailed technical specifications for MAG 5000/6000 flowmeters.

Accuracy

Presents accuracy figures and graphs based on flow velocity and conditions.

Output Characteristics

Details characteristics of current, frequency, pulse, and relay outputs.

Cable Data

Provides specifications for electrode and coil cables.

Cable Requirements

Outlines requirements for ambient temperature, capacitance, and cable glands.

Spare PartsAccessories

Ordering of Spare Parts

Information on finding the latest ordering data for spare parts online.

Spare Parts

Lists common spare parts and accessories with images.

Sun Shield

Details the sun shield accessory.

Menu Diagrams

Transmitter Menu Overview

Provides a high-level overview of the transmitter's menu structure.

Basic Settings Diagrams

Detailed diagrams of the basic settings menu options.

Reset Mode Diagrams

Diagrams illustrating reset mode options for totalizers and settings.

Operator Menu Setup Diagrams

Diagrams for customizing the operator menu layout and displayed text.

Change Password Diagrams

Diagrams showing the process for changing the transmitter's password.

Factory Settings

Transmitter Factory Settings

Table listing default factory settings for various parameters.

50 Hz Dimension Dependent Qmax

Table of Qmax values for different pipe diameters at 50 Hz.

60 Hz Dimension Dependent Qmax

Table of Qmax values for different pipe diameters at 60 Hz.

50 Hz Dimension Dependent VolumePulse and Batch

Tables specifying volume, pulse, and batch settings by dimension at 50 Hz.

60 Hz Dimension Dependent VolumePulse and Batch

Tables specifying volume, pulse, and batch settings by dimension at 60 Hz.

Product Documentation and Support

Product Documentation

Information on accessing product documentation online and via mobile app.

Technical Support

Details on obtaining technical support through requests, online services, and representatives.

Related product manuals