Device-specific Safety Instructions
Safety Manual
20 Operating Instructions, 06/2012, A5E03433511-05
3.7 Safety characteristics
The safety characteristics necessary for use of the system are listed in the SIL declaration of
conformity. These values apply under the following conditions:
● The SITRANS SL is only used in safety-related systems with a low demand mode for the
safety function
● When external sensors for process temperature and process pressure are used they
have to be considered as part of the Safety related system.
● Purging of sensors must be considered as part of the Safety related system.
● The safety-related parameters/settings (see chapter Settings (Page 16)) have been
entered
by local operation and checked before starting safety-instrumented operation.
● The SITRANS SL is blocked against unintentional and unauthorized changes/operation.
● All used materials are compatible with process conditions.
● The MTTR after a device fault is 72 hours.
● The logic solver (PLC) has to be configured to detect low range (<3.6 mA) failure of the
SITRANS SL (fail low) and will recognize these as internal failure of the devices and not
cause a spurious trip.
See also
Certificate of Conformity SITRANS SL Functional Safety
(http://support.automation.siemens.com
/WW/view/en/10806991/134200)