EasyManua.ls Logo

Siemens SITRANS TS500 User Manual

Siemens SITRANS TS500
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SITRANS T
Temperature sensors
SITRANS TS100/TS200/TS300/
TS500/TSinsert/TSthermowell
Operating Instructions
08/2020
A5E47810090-AA
Introduction
1
Safety notes
2
Description
3
Installing/mounting
4
Connecting
5
Commissioning
6
Operating
7
Parameter assignment
8
Service and maintenance
9
Diagnostics and
troubleshooting
10
Technical data
11
Dimension drawings
12
Product documentation and
support
A
Remote operation
B

Table of Contents

Other manuals for Siemens SITRANS TS500

Questions and Answers:

Siemens SITRANS TS500 Specifications

General IconGeneral
TypeTemperature Transmitter
Housing MaterialAluminum
DisplayLCD
Accuracy±0.1 °C
Output Signal4-20 mA
CommunicationHART
InputRTD, Thermocouple
Operating Temperature-40 to 85 °C
Ambient Temperature-40 to 85 °C
MountingDIN rail mounted
Protection ClassIP66

Summary

Safety notes

Installing/mounting

Connecting

Commissioning

Operating

Changing parameter values

Instructions on how to modify parameter values via the device display.

Locking the device

Methods to protect device settings from unauthorized changes.

Enable write protection with write protection switch

Procedure to enable write protection using the physical switch.

Parameter assignment

Overview of parameters and functions

Lists and groups parameters accessible via local or remote operation.

Parameter assignment with USB modem and SIPROM T

Steps for assigning parameters using the USB modem and software.

Parameter assignment over device with display

Detailed parameter configuration using the device's local display.

Change User PIN [16]

Procedure to change the user PIN for device security.

User PIN [18]

Enables or disables the user PIN for parameter access control.

Assigning parameters using remote operation

Configuring parameters remotely via software tools.

Sensor calibration

Guides for calibrating the sensor using one or two points.

Current output

Configuration of output current settings, including fault currents.

Setting the fault current of the internal transmitter with switch to ≥ 21 mA

Procedure to set the transmitter fault current via a switch.

Service and maintenance

Basic safety notes

Critical safety warnings for maintenance and repair tasks.

Recalibration

Recommendations for recalibration intervals and conditions.

Diagnostics and troubleshooting

Diagnostic messages

Lists diagnostic message IDs, causes, and recommended actions.

Technical data

Gas hazardous area: Ex i / IS / Ex nA/ec / NI

Ambient temperature limits for gas hazardous areas.

Gas hazardous area: Ex d / XP

Ambient temperature limits for flameproof enclosures.

Dust hazardous area: Ex i / IS / Ex tb / DIP

Ambient temperature limits for dust hazardous areas.

Remote operation

SIMATIC PDM

Overview of SIMATIC PDM software for device management.

Related product manuals