SITRANS T
Temperature sensors
SITRANS TS100/TS200/TS300/
TS500/TSinsert/TSthermowell
Operating Instructions
08/2020
A5E47810090-AA
Introduction
1
Safety notes
2
Description
3
Installing/mounting
4
Connecting
5
Commissioning
6
Operating
7
Parameter assignment
8
Service and maintenance
9
Diagnostics and
troubleshooting
10
Technical data
11
Dimension drawings
12
Product documentation and
support
A
Remote operation
B

Table of Contents

Other manuals for Siemens SITRANS TSinsert

Questions and Answers

  • A
    Allen SmithSep 13, 2025
    What does 'Drift detected, ground voltage offset to terminal 3' mean on my Siemens SITRANS TSinsert Temperature Controller?
    • L
      Lauren MendozaSep 13, 2025
      If your Siemens Temperature Controller displays 'Drift detected, ground voltage offset to terminal 3', it means a critical measurement error is detected on ground voltage offset to terminal 3. Reconnect or repair the sensor. If the problem persists, contact Technical Support.
  • S
    Shelby LongAug 25, 2025
    Why does my Siemens SITRANS TSinsert display 'No symbol is displayed' after a configuration change?
    • J
      Jeremy WardAug 25, 2025
      If your Siemens Temperature Controller displays 'No symbol is displayed' and the device configuration has changed due to a work process, reset the configuration bit memory to delete the diagnostic message.
  • J
    Jennifer DunnAug 25, 2025
    Why does my Siemens Temperature Controller display 'No symbol is displayed' when the device state is ok?
    • R
      Ronald TuckerAug 26, 2025
      If your Siemens Temperature Controller displays 'No symbol is displayed' and the device state is ok with no errors from active diagnostics, no action is required.
  • N
    Nicholas DixonSep 23, 2025
    Why does my Siemens SITRANS TSinsert Temperature Controller show 'Configuration not supported by device'?
    • K
      Kathleen TaylorSep 23, 2025
      If your Siemens Temperature Controller displays 'Configuration not supported by device' because the configuration is temporarily invalid for less than 3 seconds, for example, during parameter download, no further action is required.
  • F
    Frank ConnerSep 13, 2025
    What to do if Siemens SITRANS TSinsert Temperature Controller shows electronics defect?
    • J
      Joseph MartinezSep 13, 2025
      If your Siemens Temperature Controller displays 'Electronics defect', a replacement of the device is recommended. Contact Technical Support.
  • U
    ulawrenceSep 22, 2025
    How to fix 'CRC16 error in input CPU configuration' on Siemens Temperature Controller?
    • C
      cmitchellSep 22, 2025
      If your Siemens Temperature Controller displays 'CRC16 error in input CPU configuration', reset the device or switch it off and back on.
  • M
    Mary RamseySep 6, 2025
    Why is 'Backup enabled' on my Siemens SITRANS TSinsert Temperature Controller?
    • M
      Michael LozanoSep 6, 2025
      If your Siemens Temperature Controller displays 'Backup enabled', it means a sensor error is detected, and the backup sensor is in use. Unplug and reconnect the sensor cable. Check if the sensor is operated out of specified limits. If the problem persists, replace the sensor.
  • S
    Susan BallSep 7, 2025
    What does 'Backup error' mean on my Siemens Temperature Controller?
    • H
      Holly HillSep 7, 2025
      If your Siemens Temperature Controller displays 'Backup error', it means a sensor error is detected at the backup sensor, and no backup is available. Unplug and reconnect the sensor cable. Check if the sensor is operated out of specified limits. If the problem persists, replace the sensor.
  • B
    brandon22Sep 23, 2025
    How to fix 'Exception error during code execution' on Siemens SITRANS TSinsert?
    • J
      jordanbriannaSep 23, 2025
      If your Siemens Temperature Controller displays 'Exception error during code execution', reset the device or switch it off and back on.
  • D
    djacobsAug 31, 2025
    What does 'Primary variable out of limits' mean on my Siemens Temperature Controller?
    • A
      Adriana BrownAug 31, 2025
      If your Siemens Temperature Controller displays 'Primary variable out of limits', it means the process value has reached the sensor limit. Review process conditions versus product specifications.

Siemens SITRANS TSinsert Specifications

General IconGeneral
Communication ProtocolHART
TypeTemperature Transmitter
Output Signal4 to 20 mA, HART
SensorRTD, Thermocouple
InputsRTD, Thermocouple
Operating Temperature-40 to 85 °C (-40 to 185 °F)
Protection ClassIP67
DisplayOptional LCD display