11.6.2 SITRANS TS500
SITRANS TS500
"Flameproof enclosure Ex d
dust explosion protection by enclosure Ex tb/tc" type of
protection
ATEX/IECEx
PTB 10 ATEX 1005 X
IECEx PTB 10.0018 X
II 1/2 G Ex d IIC T6, T4, T3 Ga/Gb
II 1/2 D Ex tb IIIC T85 °C, 100 °C or 150 °C
NEPSI
GYJ14.1004X
Ex d IIC T3/T4/T6 Ga/Gb
DIP A20/21 TA85 °C/100 °C/150 °C IP65
EACEx
RU C-DE.AA87.B.00006
Ga/Gb Ex d IIC, T6, T4, T3 X
Ex tb IIIC T85 °C,T100 °C,T150 °C Da/Db X
cCSAus
70037146
Class I, Division 1, Groups A, B, C, D T6, T4 … T1
Class I, Division 1, Groups B, C, D T6, T4 … T1 (type code 7MC65..-.....-.
(G;U)..)
Class I, Division 2, Groups A, B, C, D T6, T4 … T1
Class II Division 1 Groups E, F, G T6, T4 … T1
Class II Division 2 Groups F, G T6, T4 … T1
Class III
Ex d IIC T6, T4,T3 Ga/Gb
Ex tb IIIC T85 °C, T100 °C, T150 °C Da/Db
AEx tb IIIC T85 °C, T100 °C, T150 °C Da/Db
cFMus
FM17US0010X (USA)
FM17CA0005X (Canada)
Class I Division 1, Groups A, B, C, D; T* Ta = -40 °C up to +Tx°C
Class II, III, Division 1, Groups E, F, G; T* Ta = -40 °C up to +Tx°C
Class I, II, III, Division 2, Group A, B, C, D, F, G; T* Ta = -40°C up to +Tx °C
Class I, Zone 1, AEx d IIC T* Gb Ta = -40 °C up to +Tx °C (only FMus)
Class I, Zone 1, Ex d IIC T* Gb Ta = -40 °C up to +Tx °C (only cFM)
Zone 21 AEx tb IIIC T* Db Ta = -40 °C up to +Tx °C (only FMus)
Ex tb IIIC T* Db Ta = -40°C up to +Tx °C (only cFM)
Type 4X, IP66/67
See also
Certicates (
http://www.siemens.com/processinstrumentation/certicates)
Product documentation (Page 189)
Technical data
11.6 Certicates and approvals
SITRANS TS100/TS200/TS300/TS500/TSinsert/TSthermowell