SITRANS T
Temperature sensors
SITRANS TS100/TS200/TS300/
TS500/TSinsert/TSthermowell
Operating Instructions
08/2020
A5E47810090-AA
Introduction
1
Safety notes
2
Description
3
Installing/mounting
4
Connecting
5
Commissioning
6
Operating
7
Parameter assignment
8
Service and maintenance
9
Diagnostics and
troubleshooting
10
Technical data
11
Dimension drawings
12
Product documentation and
support
A
Remote operation
B

Table of Contents

Other manuals for Siemens SITRANS TSinsert

Questions and Answers

  • S
    Shelby LongAug 25, 2025
    Why does my Siemens SITRANS TSinsert display 'No symbol is displayed' after a configuration change?
    • J
      Jeremy WardAug 25, 2025
      If your Siemens Temperature Controller displays 'No symbol is displayed' and the device configuration has changed due to a work process, reset the configuration bit memory to delete the diagnostic message.
  • J
    Jennifer DunnAug 25, 2025
    Why does my Siemens Temperature Controller display 'No symbol is displayed' when the device state is ok?
    • R
      Ronald TuckerAug 26, 2025
      If your Siemens Temperature Controller displays 'No symbol is displayed' and the device state is ok with no errors from active diagnostics, no action is required.
  • A
    Andrew RamirezAug 26, 2025
    Why does my Siemens SITRANS TSinsert Temperature Controller show out of specification?
    • M
      Matthew ReyesAug 27, 2025
      If your Siemens Temperature Controller indicates 'Out of specification', it means the device has detected deviations from permissible ambient or process conditions. Check the ambient temperature or process conditions, and if possible, install the device at a different location.
  • V
    Vernon FryAug 27, 2025
    What to do if Siemens SITRANS TSinsert shows 'Function test' due to incomplete safety validation?
    • M
      myerszacharyAug 27, 2025
      If your Siemens Temperature Controller displays 'Function test' because safety validation is not complete, acknowledge the safety event in the Functional Safety menu and repeat safety commissioning.
  • J
    Jessica BooneAug 27, 2025
    How to troubleshoot a Siemens Temperature Controller failure related to hardware configuration?
    • W
      William ParksAug 28, 2025
      If your Siemens Temperature Controller displays 'Failure' due to parameter setting, connection error, or configuration error in the hardware, check the hardware configuration of the device using the HMI or engineering system.
  • J
    julia95Aug 28, 2025
    What does 'Maintenance required' mean on my Siemens Temperature Controller?
    • D
      davidthompsonAug 28, 2025
      If your Siemens Temperature Controller displays 'Maintenance required', it means that while the output signal is still valid and no functional restrictions have been determined, the wear reserve will most likely be exhausted in the next few weeks. Plan maintenance for the device.
  • D
    Deborah YatesAug 29, 2025
    How to resolve 'Function test' on Siemens SITRANS TSinsert Temperature Controller when the output signal is frozen?
    • S
      Steven PetersonAug 29, 2025
      If your Siemens Temperature Controller displays 'Function test' because the output signal is temporarily invalid (e.g., frozen) due to work being performed on the device, use manual mode over HMI or disable the engineering system.
  • E
    ewallerAug 30, 2025
    How to fix loop current saturation on Siemens Temperature Controller?
    • M
      Matthew McmillanAug 30, 2025
      If your Siemens Temperature Controller displays 'Loop current in saturation', it means the loop current has reached its upper (or lower) saturation limit and cannot increase (or decrease) any further. Adjust loop current scaling.
  • H
    Haley BrownAug 23, 2025
    Why does my Siemens SITRANS TSinsert display 'No symbol is displayed'?
    • S
      Sheila HoustonAug 23, 2025
      If your Siemens Temperature Controller displays 'No symbol is displayed' and at least one process value violates one of the process tolerance limits set in the device parameters, check the parameter settings for limits for this application.
  • C
    Christopher AdamsAug 31, 2025
    What does 'Non-primary variable out of limits' mean on my Siemens Temperature Controller?
    • J
      Joseph SwansonSep 1, 2025
      If your Siemens Temperature Controller displays 'Non-primary variable out of limits', it means a process value that is not mapped to the primary variable has reached the sensor limit. Review process conditions versus product specifications.

Siemens SITRANS TSinsert Specifications

General IconGeneral
Communication ProtocolHART
TypeTemperature Transmitter
Output Signal4 to 20 mA, HART
SensorRTD, Thermocouple
InputsRTD, Thermocouple
Operating Temperature-40 to 85 °C (-40 to 185 °F)
Protection ClassIP67
DisplayOptional LCD display