SITRANS T
Temperature sensors
SITRANS TS100/TS200/TS300/
TS500/TSinsert/TSthermowell
Operating Instructions
08/2020
A5E47810090-AA
Introduction
1
Safety notes
2
Description
3
Installing/mounting
4
Connecting
5
Commissioning
6
Operating
7
Parameter assignment
8
Service and maintenance
9
Diagnostics and
troubleshooting
10
Technical data
11
Dimension drawings
12
Product documentation and
support
A
Remote operation
B

Table of Contents

Other manuals for Siemens SITRANS TSinsert

Questions and Answers

  • T
    Todd HoltSep 1, 2025
    Why does my Siemens Temperature Controller show an electronics temperature alarm?
    • L
      Lisa WrightSep 1, 2025
      If your Siemens Temperature Controller displays 'Electronics temperature alarm', it means the device is operated outside its specified temperature range. Check the operating temperature.
  • A
    Allen SmithSep 13, 2025
    What does 'Drift detected, ground voltage offset to terminal 3' mean on my Siemens SITRANS TSinsert Temperature Controller?
    • L
      Lauren MendozaSep 13, 2025
      If your Siemens Temperature Controller displays 'Drift detected, ground voltage offset to terminal 3', it means a critical measurement error is detected on ground voltage offset to terminal 3. Reconnect or repair the sensor. If the problem persists, contact Technical Support.
  • D
    djacobsAug 31, 2025
    What does 'Primary variable out of limits' mean on my Siemens Temperature Controller?
    • A
      Adriana BrownAug 31, 2025
      If your Siemens Temperature Controller displays 'Primary variable out of limits', it means the process value has reached the sensor limit. Review process conditions versus product specifications.
  • S
    Sherry MartinSep 15, 2025
    How to fix 'Loop current read back error' on Siemens SITRANS TSinsert Temperature Controller?
    • A
      adamsjacobSep 15, 2025
      If your Siemens Temperature Controller displays 'Loop current read back error' because the loop current does not correspond to the expected value, check DAC trim settings and restore to factory DAC calibration.
  • E
    edwardsjosephSep 14, 2025
    What to do if Siemens SITRANS TSinsert Temperature Controller displays 'Volatile memory check failure Maintenance alarm'?
    • B
      Brian SampsonSep 14, 2025
      If your Siemens Temperature Controller displays 'Volatile memory check failure Maintenance alarm' because of a device electronics error, restart the device. If the error continues, the device electronics may have a defect. Repair is required. Contact Technical Support.
  • U
    ulawrenceSep 22, 2025
    How to fix 'CRC16 error in input CPU configuration' on Siemens Temperature Controller?
    • C
      cmitchellSep 22, 2025
      If your Siemens Temperature Controller displays 'CRC16 error in input CPU configuration', reset the device or switch it off and back on.
  • J
    Jessica BooneAug 27, 2025
    How to troubleshoot a Siemens Temperature Controller failure related to hardware configuration?
    • W
      William ParksAug 28, 2025
      If your Siemens Temperature Controller displays 'Failure' due to parameter setting, connection error, or configuration error in the hardware, check the hardware configuration of the device using the HMI or engineering system.
  • V
    Vernon FryAug 27, 2025
    What to do if Siemens SITRANS TSinsert shows 'Function test' due to incomplete safety validation?
    • M
      myerszacharyAug 27, 2025
      If your Siemens Temperature Controller displays 'Function test' because safety validation is not complete, acknowledge the safety event in the Functional Safety menu and repeat safety commissioning.
  • A
    Andrew RamirezAug 26, 2025
    Why does my Siemens SITRANS TSinsert Temperature Controller show out of specification?
    • M
      Matthew ReyesAug 27, 2025
      If your Siemens Temperature Controller indicates 'Out of specification', it means the device has detected deviations from permissible ambient or process conditions. Check the ambient temperature or process conditions, and if possible, install the device at a different location.
  • J
    Jennifer DunnAug 25, 2025
    Why does my Siemens Temperature Controller display 'No symbol is displayed' when the device state is ok?
    • R
      Ronald TuckerAug 26, 2025
      If your Siemens Temperature Controller displays 'No symbol is displayed' and the device state is ok with no errors from active diagnostics, no action is required.

Siemens SITRANS TSinsert Specifications

General IconGeneral
Communication ProtocolHART
TypeTemperature Transmitter
Output Signal4 to 20 mA, HART
SensorRTD, Thermocouple
InputsRTD, Thermocouple
Operating Temperature-40 to 85 °C (-40 to 185 °F)
Protection ClassIP67
DisplayOptional LCD display