Siemens Synco™ living Operating instructions CE1B2707en
Building Technologies Central apartment unit QAX910 23.08.2008
Activating simulation of presence
The effect of presence simulation (release and function) can be set individu-
ally for each switching group:
Release
“Release” allows you to control switching groups in dependence of a time
switch or as a combination of time switch and twilight switch.
Main menu > Switching groups > Switching group X > Presence simulation
> Release:
The following settings are available:
--- Inactive – no presence simulation for
this switching group
With time switch (T’swi) Presence simulation enabled according
to “Time swi presence simulation“
With time swi + twilight swi
(T’swi + twil)
Presence simulation enabled according
to “Time swi presence simulation“ and
twilight switch signals DARK
Switching group 1 2 3 4
Factory setting --- --- --- ---
Your setting ---
T’swi
T’swi+ twil
---
T’swi
T’swi+ twil
---
T’swi
T’swi+ twil
---
T’swi
T’swi+ twil
Switching group 5 6 7 8
Factory setting --- --- --- ---
Your setting ---
T’swi
T’swi+ twil
---
T’swi
T’swi+ twil
---
T’swi
T’swi+ twil
---
T’swi
T’swi+ twil
T’swi Time switch
twil Twilight switch
Example of release according to the time switch:
On
Off
ABC D EF
t
On
Off
On
Off
B2707Z01
A
B
C
Time program presence simulation (On, Off)
Absence (On, Off)
Release of simulation (On, Off)
t Time
A
B
C