6 - USE
Parameter Description
Access
level
Adjustment
range
Default value
Custom
value
Cmd Volt
1 0mV
2 0mV
3 0mV
4 0mV
Absolute value of 0-10V signal sent to heat generators 1, 2, 3, 4.
Installer
Zones State State of the heating circuits
Zone 1
System N/A
Installer Value Value
Type of Zone For how it is set in Conguration>Zones->3 way valve->Type of Zone parameter
Installer Value Value
RT input State of the RT input (Yes = heat demand; No = No heat demand)
Installer Value Value
Action As set in Parameters>Zones->Action parameter. It is not visible if the room sensor is connected
(Conguration>Zones>Zone Mode 1> FixSp-RS/ Outd Reset-RS)
Installer Value Value
Heating Mode As set in Conguration>Zones>Zone Mode parameter
Installer Value Value
Request Heat request yes or no. It is not visible if the room sensor is connected (Conguration>Zones>Zone Mode 1>
FixSp-RS/ Outd Reset-RS)
Installer Value Value
Selected setp Actual setpoint. It is not visible if the room sensor is connected (Conguration>Zones>Zone Mode 1> FixSp-
RS/ Outd Reset-RS)
Installer Value Value
3 way valve State 3 way valve state
Installer Value Value
Supply sens Current circuit supply temperature
Installer Value Value
Pump control On or off
Installer Value Value
Valve control Opening (100%) or closing (0%) percentage of the mixing valve
Installer Value Value
Pump State of the circuit pump
Installer Value Value
Vlv 3pt Open State of the relay that controls the opening of the mixing valve
Installer Value Value
Vlv 3pt Close State of the relay that controls the closing of the mixing valve
Installer Value Value
Zone 2
Same menu as for “Zone 1”
Installer
Zone 3
Same menu as for “Zone 1”
Installer
Zone 4
Same menu as for “Zone 1”
Installer
Zone 5
Same menu as for “Zone 1”
Installer
Outputs rotat. state Rotation state of the heat generators
Installer
Heating Heat generators to be used for heating
Installer
Mode As set in Parameters>Outputs rotation>Mode menu
Installer Value Value
Fix rotation
Installer
Interval Rotation time
Installer Value Value
Base time rotation
Installer