www.sigineer.com
10
Battery
Type
Selector
Description
Boost
Charge(C.V)
Float
Charge
Boost
Charge(C.V)
Float
Charge
Boost
Charge(C.V)
Float
Charge
For 12Vdc Models
For 24Vdc Models
For 48Vdc Models
0
Charger Off
1
Gel USA
14
13.7
28
27.4
56
54.8
2
AGM 1
14.1
13.4
28.2
26.8
56.4
53.6
3
AGM 2
14.6
13.7
29.2
27.4
58.4
54.8
4
Sealed lead acid
14.4
13.6
28.8
27.2
57.6
54.4
5
Gel EURO
14.4
13.8
28.8
27.6
57.6
55.2
6
Open lead acid
14.8
13.3
29.6
26.6
59.2
53.2
7
Calcium
15.1
13.6
30.2
27.2
60.4
54.4
8
De sulphation
(4 hours)
15.5
15.5
31
31
62
62
9
Lithium Battery
Customized
Customized
Customized
Customized
Customized
Customized
De-sulphation
The de-sulphation cycle on switch position 8 is marked in red because this is a very dangerous setting if you
do not know what you are doing. Before ever attempting to use this cycle you must clearly understand what
it does and when and how you would use it.
What causes sulphation? This can occur with infrequent use of the batteries, nor if the batteries have been
left discharged so low that they will not accept a charge. As the saying goes, desperate diseases must have
desperate remedies. This cycle is a very high voltage charge cycle especially designed to try to break down
the sulphated crust that is preventing the plates from taking a charge and thus allow the plates to clean up
and accept a charge once again.
Warning!
The de-sulphation charging should not be carried out on batteries with good conditions.
For Sigineer Powers model of APC6024D and APC6048D Inverter chargers, the battery type selector
position of 9 is customized with special charging algorithm for lithium battery modules from Tesla Model
S.
The algorithm has only Bulk Charging (Constant Current) to charge the battery, when the battery is charged
to high voltage alarm, the charger will shut off and inverter goes to battery mode.
Model #
APC6024D
APC6048D
Low Battery Cut Off
18V
36V
Low Battery Voltage Alarm/ Charger Activation
23.5V
47V
High Battery Voltage Alarm/ Charger Cut Off
25.25V
50.5V
High Battery Cut Off
25.5V
51V

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sigineer Power PSW71512NC and is the answer not in the manual?

Sigineer Power PSW71512NC Specifications

General IconGeneral
BrandSigineer Power
ModelPSW71512NC
CategoryBattery Charger
LanguageEnglish

Related product manuals