Operating Manual SIGMA 2-5, page 30 of 55
03/06
4.1.1 Start-key
This key can be used for the following:
starting centrifuge operation,
terminating a previously started deceleration process and restarting the
centrifuge,
shifting to short-run (refer to chapters 4.2.3.2.1, 4.2.3.2.2).
saving a program. The parameters speed and time preselection can be
locked,
thereafter a change is impossible. Starting and stopping the centrifuge and
opening of the lid is always possible.
Open centrifuge lid. Press the start-key 3 x and hold for approx. 2 seconds
when pressing for the third time. A flashing bar appears in the time and/or
speed panel. Cancellation of this function occurs in the same way.
The centrifuge can be started when
the lid is closed,
the Start-key is illuminated.