OPERATING INSTRUCTIONS, Continued
4
. Notch the seal with a sealing tool. Note that the
tensioner automatically keeps tension on the strap.
Inspect the seal to make sure the sealing tool has
properly formed a joint.
5. Before shutting of the air , break the strap at the seal by swinging
the tensioner up and down as shown. DO NOT EXCEED 90
o
MOVEMENT. If the tool is swung too far forward, damage to
the seal will occur and the strap will not break off.