1 8 MA503 Datum 08.01.2001 Art.Nr. 79539 Z.Nr. 8664078 Änd.Stand 2/01
Action: Leave incremental measurement
function as descriped in chapter 8 or proceed
as follows:
1. Enter into programming mode
2. Program parameter '_FrEL' to "on"
3. Leave programming mode
4. Leave incremental measurement function
as descriped in chapter 8
5. Enter programming mode again
6. Program parameter '_FrEL' to "oFF"
7. Leave programming mode
13. Application Examples
Length measurement
Required: Display accuracy 1/10 mm. Display
shall be zeroed via function key
Designation Display Progr. value
Resolution _rES_ 0.1
Reference value _rEF_ 00000.0
Offset _oFF_ 00000.0
Decimal point _dP_ 0.0
Counting direction _dIr_ UP
Switch-off method _AUto_ oFF
Last value memory _rSTo_ oFF
Delayed switch-off _4_oFF oFF
Access: reset _F_Abs on
Access: increm. meas. _F_rEL oFF
Access: ref. value _F_rEF oFF
Access: offset _F_oFF oFF
Processor speed _SPEEd HI
Language _LAn_ E
Angle measurement
Required: display range 0 ... 360°; display
accuracy 1/10° . Display shall be zeroed via
function key. Automatically switch-off after 10min.
Conditions: circular disk with Ø 300 mm; resul-
ting total circumference: U = π x 300 mm =
942,48 mm
The programmable factor is calculated as fol-
lows: FAC = total display range [1/10°] / circum-
ference [1/100 mm]
3600 / 94248 = 0,038200
Designation Display Progr. value
Resolution _rES_ FrEE
Calculating factor _FAC_ 0.03820
Reference value _rEF_ 00000.0
Offset _oFF_ 00000.0
Decimal point _dP_ 0.0
Counting direction _dIr_ UP
Switch-off method _AUto_ on
Switch-off time PErIod 600
Last value memory _rSTo_ oFF
Delayed switch-off _4_oFF oFF
Access: reset _F_Abs on
Access: increm. meas. _F_rEL oFF
Access: ref. value _F_rEF oFF
Access: offset _F_oFF oFF
Processor speed _SPEEd HI
Language _LAn_ E