MA503 Datum 08.01.2001 Art.Nr. 79539 Z.Nr. 8664078 Änd.Stand 2/01 1 9
Display Designation / value range Standard programm. your programming
_rES_ resolution (mm, In=inch) 0.1
1, 0.1, 0.05, 0.01, In 0.01, In 0.001,
FrEE
_FAC_ calculation factor (only if resolution 0.00000
has been programmed to "FrEE")
0.00001 ... 9.99999
_rEF_ reference value 00000.0
-999999 ... (+)999999
_oFF_ offset value -999999 ... (+)999999 00000.0
_dP_ decimal point (only if resolution has 0.0
been programmed "FrEE") 0. to 0.000
_dIR_ counting direction UP, dn dn
_AUto_ switch-off method on , oFF oFF
PErIod switch-off time (in minutes)(only for 009
switch-off methods 'on') 009... 999
_rSTo__ last value memory on , oFF oFF
_4_oFF Delayed switch-off: on, oFF oFF
_F_AbS access reset function: on , oFF on
_F_rEL access increm. measurement: oFF
on , oFF
_F_rEF access reference value: oFF
on , oFF
_F_oFF access offset value: oFF
on , oFF
_SPEEd Processor speed: HI , Lo Lo
_LAn_ language d, E d
Appendix: Parameter list