SDI 3500 D4
10 
GB
IE
Operation
The induction fields
The induction fields 1/3 have the following output levels:
Power levels L01 L02 L03 L04 L05 L06 L07 L08 L09 L10
Left induction
field 1 (in watts)
200 400 600 800 1000 1200 1400 1600 1800 2000
Right induction
field 3 (in watts)
200 400 600 800 1000 1250 1500
Both induction fields 1/3 have 19 temperature levels:
Temperature levels
in °C
60 70 80 90 100 110 120 130 140 150
160 170 180 190 200 210 220 230 240 -
Although the two induction fields 1/3 are optically identical, the left induction
field 1 is more powerful than the right one 3. Therefore, bear in mind that you
can cook the same amount of food more quickly on the left induction field 1
and it can also burn onto the pan more quickly.
Safety cut-off
For safety reasons, the pan detection function automatically switches the
appliance into standby mode when you remove the pan from the induction
field 1/3 or do not place a pan on it at all.
If you remove the pan from the induction field 1/3, you will hear a beep
after a few seconds which will repeat for approx. 1 minute. The display t
shows the error "(". If you place the pan back on the induction field 1/3
within this time, the previously defined settings will be retained. Otherwise,
the "(" message will disappear after 1 minute and the appliance will switch
to standby mode.
NOTE
As long as the temperature of the induction field 1/3 remains above
60°C, "+" will be shown on the display t.
IB_374031_SDI3500D4_LB8.indb 10 24.09.2021 11:44:59