Loading...
7
GB
5. How to use
Remove all packing material.
Remove all transport packing material.
Strip off the foil from the operating pan-
el.
Check to ensure that all parts are pre-
sent and undamaged.
1. Place the device on a level, dry and
solid surface.
2. Let the device rest in its working posi-
tion for about 30 minutes, so that the
coolant fluid can settle.
3. Make sure that the float at the left-hand
side of the water tank 5 can move freely.
4. Check that the water tank 5 is inserted
correctly. If it is installed incorrectly, or
if the water tank has been removed, the
LED 12 TANK FULL will illuminate.
5. Connect the mains plug 10 to a
grounded power socket.
6. Notes on operation
If the relative humidity in residential
rooms is continuously excessive, the
cause should be found and rectified.
(Continuous ventilation - i.e. for several
years - is generally not reasonable.)
The optimum ambient temperature for
removing humidity from the air is 5 °C
to 35 °C. Below 5 °C, the use of a de-
humidifier is not helpful, as there is only
relatively little humidity in the air.
During operation, the room temperature
may rise by between 1 °C and 4 °C,
depending on room size. This is normal.
Automatic defrosting
In order to prevent the device from freezing
over while in continuous operation, it de-
frosts itself automatically. To do this, the de-
humidification process is interrupted, and
the motor switches to its highest setting.
The intervals at which this happens vary.
7. Operation
7.1 Switching on and off
By pressing the button 16 STAND-BY,
you can switch the device on and off.
The corresponding LEDs illuminate or go
out.
- The device will start with the setting
last selected.
- If the device has failed due to a pow-
er outage, has been disconnected
from the mains power or stopped by
the overheating protection system, it
will start in the AUTOMATIC mode.
If a timer has been set, the device will
shut down after the time has run out (1-
12 hours).
If a value has been set for relative hu-
midity in the CONTINUOUS mode, the
device will stop when the value has
been reached, and re-start when the val-
ue is exceeded again.
The device switches off when the water
tank is full or has been removed.
Conditions
Defrosting
Temperature:
over 20 °C
no defrosting
Temperature:
12 °C to 20 °C
after 40 minutes dehu-
midification,
8 minutes defrosting
Temperature:
5 °C to 12 °C
after 25 minutes dehu-
midification,
10 minutes defrosting
Temperature:
under 5 °C
operation not possible
__RP89301_B4.book Seite 7 Freitag, 19. April 2013 7:28 19