StreamCaster MIMO Radio User Manual 4/30/19
10017C000 Silvus Technologies Confidential Page
148
12. Troubleshooting
12.1 LED Issues
If flashing red LED is present, radio is in safe boot mode. Click save and apply to resume
normal operation.
If LED is orange and node won’t connect to another node, click “restore factory defaults”
on both radios to ensure all settings are reverted to factory settings.
12.2 Intermittent Link
In a long range scenario if SNR is good but link drops unexpectedly check link distance
parameter and make sure that the link distance is set the same on all radios and
sufficiently large enough.
Check interference levels as strong interference can result in an intermittent link.