StreamCaster MIMO Radio User Manual 4/30/19
10017C000 Silvus Technologies Confidential Page
SC3500/SC3800:
Environmental
Standard
Extended Temperature
Operating Temp.
-40° - +55° C
-40° - +65° C
IP Rating
IP-67 (Dust / Immersion in water up to 1m)*
(Ingress Protection)
*Must have all connectors mated and use IP67 or better cables/antennas
Mechanical Chassis
Standard
Extended Temperature
Dimensions
3.25” x 5.75” x 4”
H x L x W
4.5” x 5.75” x 4”
H x L x W
Weight
3.7 lbs. (1.68 kg/59.2 oz)
4 lbs. (1.81 kg/64 oz)
Color
c. FED-STD-595B-34094 (green 383)
d. Black anodized
e. CARC (Chemical Agent Resistant Coating)
Mounting
4-hole mounting patterns (non-penetrating)
located on both rear and bottom sides
Connectors
RF
TNC (f) (4 each)
Data / Control
Ethernet cable, Mighty-Mouse 801 Heavy-Duty, Double-Start 10
conductor (f)
Power
Mighty-Mouse 801 Heavy-Duty, Double-Start 10 conductor (m)
(RS232 / GPS Support)
Controls and Indicators
Power
On / Off Toggle with detent
Status Indicator
Tri-Color LED
Power Requirements
Voltage
9 20 VDC
Consumption
12W 22.5W (Duty Cycle and Frequency Dependent)
24.5 W 80% Tx Duty Cycle
Mechanical OEM Board Stack
Dimensions
1.9” x 5.25” x 2.9” H x L x W
5.75
4.50
3.25
Extended Temperature Variant
Standard Temperature Variant
ANT1 ANT4ANT3ANT2
STATUS PWROFF ETH